Access Control Accessories (1,204)

Aritech 2507A-L is a wide gap armoured cable contact designed to be installed in commercial and industrial environments where a rugged sealed unit is required. It is ideal for metal doors, overhead doors, fences and gates. It features a high strength extruded aluminum housing and is completely encapsulated in polyurethane potting compound. The 2507A-L also features a SPDT switch.
Add to Compare
Aritech 2507AD-L is a wide gap armoured cable contact designed to be installed in commercial and industrial environments where a rugged sealed unit is required. It is ideal for metal doors, overhead doors, fences and gates. It features a high strength extruded aluminum housing and is completely encapsulated in polyurethane potting compound. The 2507AD-L also features a DPDT switch.
Add to Compare
Magnet tamper interlock shields intervening magnetic flux Ultimate high security contact design Undefeated by prominent testing laboratories Triple-biased reeds make defeat with external magnets virtually impossible Magnetic field tamper Options include remote test, resettable current limiting device, custom modifications available
Add to Compare
Altronix ACM8 converts one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM8 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
Add to Compare
Altronix ACMS8/ACMS8CB are UL listed sub-assemblies designed to be used in Altronix wall and rack mount enclosures. Input power to ACMS8/ACMS8CB is to be derived from eFlow series power supplies. Dual input design allows power to be steered from two (2) independent low voltage 5 to 24 VDC power sources into eight (8) independently controlled fuse or PTC protected outputs. In ACMS8, these power outputs can also be converted to dry form “C” contacts. Outputs are activated by an open collector sink, normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACMS8/ACMS8CB will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect featureis individually selectable for any or all of the eight (8) outputs. The spade connectors allow you to daisy chain power to multiple ACMS8/ACMS8CB modules. This feature allows you to distribute the power over more outputs for larger systems.
Add to Compare
Altronix ACM8E converts one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM8E will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
Add to Compare
CEM ECM/200/000 Ethernet communication module with PSU and enclosure is a serial to Ethernet converter that enables CEM serial communication devices (such as the S600s reader range, InfoProx reader and the DCM controllers), to connect to the AC2000 central system via an Ethernet LAN. The ECM can support a chain of up to 16 RS485 CEM devices connected to a single channel (up to a maximum length of 1.2 km). This provides a cost effective means of connecting a group of serial readers to the AC2000 system from a single Ethernet point.
Add to Compare
AnywhereUSB is remote networking solution to utilise USB over IP technology. This Ethernet-attached solution provides five USB ports, which deliver the same Plug-and-Play as onboard USB ports. Peripheral devices can be centrally managed and monitored from a remote server or PC via an IP address. Applications include relocating the host PC to a back office, centralised management, kiosk, ATM or pay-at-the-pump manufacturers, restaurant kitchens, access control systems, industrial automation or any environment that is volatile. AnywhereUSB is compatible with bulk or interrupt type USB devices such as bar-code scanners, printers, fingerprint scanners, mice, pole displays, card readers and more.
Add to Compare
Aritech 3555-B bill trap is specifically designed for use inside cash drawers. Bills are inserted between the lever and the base plate. Once the bills are removed, contact is made creating an alarm condition. The unit is constructed of Delrin plastic for long life and features a SPDT reed switch for activation. The reed is secured using exclusive polyurethane potting material. Since the unit has no mechanical switch, it is not susceptible to dust or humidity, and is not subject to wear. The device mounts easily using double-sided tape.
Add to Compare
Altronix ACM8CBE converts one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled Class 2 rated PTC protected power-limited auto-resettable outputs rated at 2.5A each. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM8CBE will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
Add to Compare
Altronix ACM4CB converts one (1) 12 to 24 volt AC or DC input into four (4) independently controlled Class 2 rated PTC protected power-limited auto-resettable outputs rated at 2A each. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The ACM4CB will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.
Add to Compare
Altronix ACM4E converts one (1) 12 to 24 VAC or VDC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4E will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.
Add to Compare
Altronix ACM4CBE converts one (1) 12 to 24 volt AC or DC input into four (4) independently controlled Class 2 rated PTC protected power-limited auto-resettable outputs rated at 2A each. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4CBE will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.
Add to Compare
Aritech 3040 panic switch activates the SPDT switch when the user pulls the actuating lever. The external LED lights and latches on the panic switch indicates that the alarm circuit has been activated. The lever is closed first to rearm the alarm switch, then the latching LED circuit is reset externally at the host panel.
Add to Compare
Aritech 3050 panic switch activates the SPDT switch when the user pulls the actuating lever. The 3050 panic switch features a glowing LED for low light visibility. The LED glows green when powered up and turns red upon activation. The panic switch contains a latching LED.
Add to CompareThe ImproX O16 16 channel output terminal is a general purpose module for use within the ImproNet access control system, and for OEM applications. The ImproX O16 is an output terminal, providing sixteen Relays for controlling door strikes and other equipment.
Add to Compare
The 1045 Series features a wider make distance, which permits faster installation, accommodates greater misalignment and works better on steel without time-consuming brackets. A wider break distance helps prevent false alarms caused by loose fitting doors. Interlogix specified contacts keep the 1045 Series from sticking or freezing on seldom-used doors.
Add to Compare
Aritech 2107 magnetic contact features open or closed loop with SPDT switch and vinyl jacketed lead. It is used to protect valuable free-standing items that are stored outdoors. The high-impact plastic housing protects the contact from corrosion or high resistance buildup.
Add to Compare
The 1045 Series features a wider make distance, which permits faster installation, accommodates greater misalignment and works better on steel without time-consuming brackets. A wider break distance helps prevent false alarms caused by loose fitting doors. Interlogix specified contacts keep the 1045 Series from sticking or freezing on seldom-used doors.
Add to Compare
BPT GB/IVT900 is an impro infrared vehicle transmitter, for use with GB/ITR901 receiver. Intended to be installed in a vehicle and mounted internally for hands-free automatic operation. It is moulded from heat-resistant polycarbonate in dark red.
Add to Compare
LSN built-in magnetic contact for release monitoring of doors and windows Tamper supervision Head-on flush mounting Installation in ferromagnetic materials is permissible by using the EG2 flush mounting housing For connecting to LSN security systems
Add to Compare
Full end-to-end authentication and encryption, preventing non-authenticated sensor inputs communicating unencrypted with controllers. Field upgradeable code with plug and play authentication for quick and secure installation. Small form factor for an easy install into almost any sensor. Sensor walk-test functionality is included, removing the need to run additional wiring.
Add to Compare
CEM IOC/300/101 input/output module includes enclosure, board & power supply/battery charger. The module provides a flexible means to monitor and control a wide array of external equipment. An addition to the Ethernet suite of devices for use on the CEM AC2000 system, it connects to the nearest network point to monitor for example windows or machinery. It features eight analogue inputs and four outputs that are used to give spare inputs/outputs on the access control system. It takes specific inputs and map them to a particular output. This allows functionality such as proximity sensors being used to turn on lights; break glass switches, sounders, releasing door locks etc.
Add to Compare
CEM IOC/300/006 input/output module board provides a flexible means to monitor and control a wide array of external equipment. An addition to the Ethernet suite of devices for use on the CEM AC2000 system, it connects to the nearest network point to monitor for example windows or machinery. It features eight analogue inputs and four outputs that are used to give spare inputs/outputs on the access control system. It takes specific inputs and map them to a particular output. This allows functionality such as proximity sensors being used to turn on lights; break glass switches, sounders, releasing door locks etc.
Add to Compare
Gallagher 8H and 4H modules support star wiring of secure high-speed HBUS devices including T Series Readers and the F22 Fence Controller to a secure Gallagher Cabinet. Star wiring HBUS devices to a controller cabinet removes the risk of one faulty connection taking down multiple devices, and enables easier fault isolation. I/O connectivity is also provided for door and equipment monitoring. Gallagher HBUS Modules are: 8H Module provides 8 HBUS ports, 24 balanced inputs and 8 relay outputs 4H Module provides 4 HBUS ports, 12 balanced inputs and 4 relay outputs.
Add to Compare
The CEM eDCM 300 Input/Output Module provides a flexible means to monitor and control a wide array of external equipment. An addition to the Ethernet suite of devices for use on the CEM AC2000 system, the eDCM 300 I/O connects to the nearest network point to monitor for example windows or machinery.
Add to Compare