Electronic Door Locks & Locking Devices (1,584)
Mortise lock available in standard function, ADB® function with 1" (25 mm) throw dead bolt, and 3/4" (19 mm) dead locking latch bolt. 2-3/4" backset.Operates on standard AA alkaline battery pack. Door thickness range 1-3/4" - 2-1/8" for standard product. Door ajar sensing mortise.
Add to Compare
Handle controlled lock Best suited in medium traffic doors Can be switched between fail-locked and fail-unlocked states Can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button Can be used both in exit doors and fire rated doors Only the outside handle is electrically controlled Can always be opened by the inside handle Mechanical opening by cylinder is always possible Recommended to be used in interior doors of business premises, public buildings, hospitals, educational premises etc.
Add to Compare
For windows and terrace/balcony doors to be locked from inside Code Handle 7810 is unlocked with a 6 digit code to be based on numbers 1 to 4. Separate lock button The code can be changed an unlimited number of times Simple installation, no cables Enhanced child security
Add to Compare
Can be switched between fail-locked and fail-unlocked states Can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button Can be used in fire rated doors Both inside and outside handles are electrically controlled Mechanical opening by cylinder or thumbturn is always possible Recommended to be used in interior doors of business premises, public buildings, hospitals, educational premises etc Indications to EAC
Add to Compare
Best suited in medium traffic doors Can be switched between fail-locked and fail-unlocked states Can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button Can be used both in exit and fire rated doors Only the outside handle is electrically controlled Can always be opened by the inside handle Mechanical opening by cylinder is always possible Recommended to be used in interior doors of business premises, public buildings, hospitals, educational premises etc Indications to EAC
Add to Compare
Best suited in medium traffic doors Can be switched between fail-locked and fail-unlocked states Can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button Can be used fire rated doors Only the outside handle is electrically controlled Mechanical opening by cylinder or thumbturn is always possible Recommended to be used in interior doors of business premises, public buildings, hospitals, educational premises etc Indications to EAC
Add to Compare
Best suited in medium traffic doors Can be switched between fail-locked and fail-unlocked states Can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button Can be used in fire rated doors Both inside and outside handles are electrically controlled Mechanical opening by cylinder or thumbturn is always possible Recommended to be used in interior doors of business premises, public buildings, hospitals, educational premises etc Indications to EAC
Add to Compare
Suitable for use in medium traffic doors Can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button Can be used in fire rated doors Can be set to function as fail locked or as fail unlocked In the fail locked setting, the lock can be opened by handle when power is on and cannot be opened by handle when power is off In the fail unlocked setting, the electrical function is reversed Automatically deadlocked when the door is closed Both outside and inside handles are electrically controlled Mechanical opening by cylinder is always possible Generally used in exterior doors of houses as well as interior- and exterior doors of offices and business premises Cannot be used in doors with door automatics Has only bolt out indication
Add to Compare
A fail unlocked type lock The door can be opened by pushing or pulling when electric control is switched off When electric control is switched off, lock can be operated by key from outside and by handle from inside In locked mode the lock is always automatically deadlocked when door closes Equipped with an integral microswitch to indicate unlocked/locked position Recommended to be used in interior and exterior doors of commercial premises, apartment buildings, etc., and are well suited for use with door automatics Can be controlled by a variety of access control systems or remote control equipment, e.g. card reader, key pad, timer or push button
Add to Compare
Handle controlled locks are best suited in medium traffic doors Can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button Can be used in fire rated doors Handle controlled locks can be set to function as fail locked or as fail unlocked In the fail locked setting, the lock can be opened by handle when power is on and cannot be opened by handle when power is off In the fail unlocked setting, the electrical function is reversed Always automatically deadlocked when the door is closed Both outside and inside handles are electrically controlled Mechanical opening by cylinder is always possible Generally used in exterior doors of houses as well as interior- and exterior doors of offices and business premises Cannot be used in doors with door automatics
Add to Compare
Can be used in exit doors The door deadlocks when closed Fulfils the standard EN 179 when used with the CY080 cylinder The door can always be opened by the key, the interior thumbturn or the push pad Generally used in interior- and exterior doors of business premises as well as exterior doors of apartment buildings Door can opened by pushing or pulling In Fail Secure version lock is open when electric control is on In Fail Safe version lock is open when electric control is off
Add to Compare
Can be switched between fail-locked and fail-unlocked settings Can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button Can be used both in exit and fire rated doors Only the outside handle is electrically controlled Can always be opened by the inside handle Mechanical opening by cylinder is always possible Recommended to be used in interior doors of business premises, public buildings, hospitals, educational premises etc
Add to Compare
Can communicate with other Hi-O locks and gather data The Hi-O technology is inside the lock case instead of a centralised database, which makes it more secure Can be used in fire rated doors Can be set to function as fail locked or as fail unlocked In the fail locked setting, the lock can be opened by handle when power is on and cannot be opened by handle when power is off In the fail unlocked setting, the electrical function is reversed Always automatically deadlocked when the door is closed Both outside and inside handles are electrically controlled Mechanical opening by cylinder is always possible Generally used in exterior doors of houses as well as interior- and exterior doors of offices and business premises Cannot be used in doors with door automatics
Add to Compare
A SCANDINAVIAN standard push & pull singlepoint lock for solid doors Best suited in high traffic doors Can be electrically controlled by access or remote-control systems Offers great solutions to environments where EAC is needed, and door usage is high Has a day function where the door is open and a secure mode where the lock is automatically deadlocked when the door is closed Mechanical opening by cylinder is always possible Additionally push & pull lock can predominantly be used with door automatics Typically used in exterior doors of business premises, hospitals, educational facilities and residential buildings Fail-unlocked version - In the event of a fire/power outage the handle will be activated allowing exits with it Certified according to EN14846, electric lock standard including a fire approval
Add to Compare
A mechanical lock with microswitches for profile doors A combination of an electric and a mechanical lock Uses Europrofile cylinders and can be opened outside by a key and inside by a handle The lock deadlocks automatically when the door closes Has a double action latch which makes the products handing reversible Additionally, it has a 20mm deadbolt which enhances the strength of the product Can be used in exit certified double leaf solutions EN179 and EN1125 certified when assembled according to instructions Suitable for panic exit doors where passing through in one direction must always be possible Exit function by handle or panic bar Suitable for fire doors Monitoring functions - Bolt deadlocked, Lock open, Door status, Handle down, Cylinder used, Sabotage loop
Add to Compare
A SCANDINAVIAN standard handle controlled singlepoint lock for profile doors Best suited in medium traffic doors Can be electrically controlled by access or remote-control systems Can be set to function as fail locked or as fail unlocked In the fail locked setting, the lock can be opened by handle when power is on and cannot be opened by handle when power is off In the fail unlocked setting, the electrical function is reversed Typically used in interior doors of offices, storages or maintenance rooms Cannot be used with door automatics Certified according to EN14846, electric lock standard including a fire approval
Add to Compare
Suitable for exterior and interior doors which are unlocked at daytime and need high security with electrical locking at night time with access control system Extra strength DHB Dynamic Hook Bolt is electrically controlled and latch is opened by handle Has latch bolt and hook bolt
Add to Compare
Both sides are equipped with handles The exterior handle only works when electrically activated, the interior handle always works Can be used with fire rated- and exit doors OneFit mortice standard Generally used in exterior doors of houses as well as interior- and exterior doors of offices and business premises Cannot be used in doors with door automatics
Add to Compare
Suitable for exterior and interior doors which are unlocked at daytime and need high security with electrical locking at night time with access control system Extra strength DHB Dynamic Hook Bolt is electrically controlled and latch is opened by handle Only deadbolt out indication Has latch bolt and hook bolt
Add to Compare
Can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button Can be used both in exit doors and fire rated doors Best suited in medium traffic doors Recommended to be used in interior doors of business premises, public buildings, hospitals, educational premises etc. The outside handle is electrically controlled Can always be opened by inside handle Mechanical opening by cylinder is always possible
Add to Compare
Suitable for exterior and interior doors which are unlocked at daytime and need high security with electrical locking at night time with access control system Extra strength DHB Dynamic Hook Bolt is electrically controlled and latch is opened by handle Only deadbolt out indication Has hook bolt
Add to Compare
Motorized bolt traction for push&pull Also possible to connect with door automatics for full hands-free operation Day/night mode , controlled egress Electric anti-tampering: if deadbolt is thrown out when door is not closed, it is withdrawn in automatically Mechanical automatic locking system Non handed, left / right Burglary-resistant due to dead bolt with 20 mm throw Suitable for fire doors Mechanical override with cylinder Back-up function: If deadbolt is withdrawn by motor and then power is cut, deadbolt is thrown out immediately (closed door) or allowed to throw out (when door is closed) Monitoring functions : Door status, Handle down, Bolt deadlocked, Bolt in, Key cylinder used, Sabotage loop Recommended to be used in high-security sites, including nuclear, power plants, public utilities, IT and telecommunications industries, museums and financial institutions
Add to Compare
Best suited in high traffic doors Can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button Can be used in exit doors Recommended to be used in exterior doors in small properties, shops and offices Can not be used in fire doors
Add to Compare